Custom Search
 
  
 
ARMY TM 9-2815-255-24 AIR FORCE TO 38G1-95-2 MARINE CORPS TM 2815-24/4 3-29.3.2  Opening Pressure Test. NOTE Actual opening pressure is less important than equal opening pressure of all nozzles.  Maximum opening pressure difference between cylinders is 100 psi (700 kPa). a. Actuate nozzle tester rapidly several times to allow valve to seat rapidly. b. Open gage valve and raise pressure to a point where gage needle falls rapidly.  This is nozzle opening pressure, and should be a minimum of 3330 psi (22,957 kPa) for a used nozzle and 3650 to 3750 psi (25,100 to 25,800 kPa) for a new nozzle. c. If nozzle opening pressure is not within specified range, replace injector, refer to paragraph 3-29.4. 3-29.3.3  Chatter and Spray Pattern Test. a. Check nozzle chatter as follows: (1) Operate nozzle tester at a pumping rate that will cause nozzle to chatter. (2) Nozzle should chatter softly, and spray pattern should be broad and finely atomized. NOTE Until the chattering range is reached, fuel will emerge in non-atomized streams. (3) Using  pumping  rate  for  proper  atomization,  refer  to  paragraph  3-29.3.1,  step  c.,  operate  tester  for  ten strokes.  The nozzle must atomize on at least eight of the ten strokes without consecutive misses. (4) If nozzle fails to meet this requirement, repeat procedure.  Nozzles which do not meet requirement after second test should be replaced. b. Check Spray Pattern. (1) Operate nozzle tester at a pumping rate that will cause the nozzle to chatter. (2) Observe  spray  pattern  and  check  for  plugged  orifices.    Partially  dogged,  chipped,  or  eroded  orifices  will cause the spray to deviate from correct angle.  Spray will be streaky, rather than finely atomized. (3) If nozzle fails to spray properly, replace it. 3-29.3.4  Leakage Test. a. Check nozzle for fuel leakage past valve seat as follows: (1) Position nozzle on nozzle tester with nozzle tip down. (2) Operate pump handle rapidly to firmly seat valve. (3) Raise pressure at nozzle to about 400 to 500 psi (2800 to 3500 kPa) under specified opening pressure. (4) Watch for an accumulation of fuel around the nozzle orifices. (5) If fuel drips from nozzle within 5 seconds, nozzle is considered defective, and must be replaced. b. Check nozzle for valve stem and guide wear as follows: (1) Position nozzle with tip slightly above the horizontal plane. Warning Place a clear, protective shield around spray zone to avoid possible personal injury from spray. 3-126


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business