Custom Search
 
  
 
ARMY TM 9-2815-255-24 AIR FORCE TO 38G1-95-2 MARINE CORPS TM 2815-24/4 FIGURE 3-19.  Testing for Grounded Windings c. Set multimeter for ohms and touch probes to two segments, refer to FIGURE 3-20.  There should be continuity at any point.  If there is no continuity, winding is open circuited.  Replace the armature if open circuited. FIGURE 3-20.  Checking for Open Circuit Windings d. Set multimeter for ohms and touch one probe to positive brush holder plate and other one to the holder plate, refer to FIGURE 3-21.  There should be no continuity.  If there is continuity, replace brush holder. FIGURE 3-21.  Checking Brush Holder 3-40


 