Custom Search
 
  
 
ARMY TM 9-2815-256-24 AIR FORCE TO 38G1-96-2 MARINE CORPS TM 2815-24/5 (4).  Remove control rod pin (4), control rod guide (6), and seal washer (9). (5).  Remove control rod assembly (5), control spring (7), control spring guide (8), and control spring bushing (10). FIGURE 3-67.  Speed Droop Governor NOTE Unless damaged, damper barrel assembly (11), damper piston (12), and damper spring (13) should not be removed from governor arm (14). (6).  Remove damper barrel assembly (11), damper piston (12), and damper spring (13) from governor arm (14). q. Press throttle shaft bushing (82, FIGURE 3-64) on shutoff lever side out approximately 1/8 inch for removal of governor hook assembly. r. Depress metering valve (45) and raise governor hook assembly (46) from metering valve arm pin. s. While holding governor arm (44) forward, pull linkage hook back slightly to disengage it from governor arm. NOTE Do not disengage linkage spring (47, FIGURE 3-64). t. Place linkage hook assembly over side of housing, refer to FIGURE 3-68. 3-91


 