ARMY TM 9-2815-256-24
AIR FORCE TO 38G1-96-2
MARINE CORPS TM 2815-24/5
FIGURE 3-104. Installing Shutoff Cam
cj.
Install two insulating tubes (85 and 86, FIGURE 3-64) on solenoid terminals. Position solenoid (16) in cover (6)
and secure with two new insulator washers (15), one washer (14), one new lockwasher (13), and two nuts (12).
ck. Position washer (11), new lockwasher (10), terminal strap (9), terminal (89), and insulator (90) on solenoid studs.
Secure with two self-locking nuts (8).
NOTE
Tighten screws (3) 35 to 45 in-lbs (4 to 5 Nm).
cl.
Position new gasket (7) and cover (6) on housing and secure with two screws (3), new lockwashers (4), washers
(5), cup (91), screw (92), and sleeve (93).
NOTE
Tighten connector (1) 43 to 53 in-lbs (5 to 6 Nm).
cm.
If removed, install new preformed packing (2) and connector (1) in cover (6).
NOTE
Tighten end cap (5, FIGURE 3-73) 30 to 37 ft-lbs (41 to 50 Nm).
cn.
Insert end cap plug tool in end cap (5, FIGURE 3-73) and tighten end cap using end cap socket (20548), refer to
FIGURE 3-105.
Change 3
3-121
|
|