ARMY TM 9-2815-256-24 AIR FORCE TO 38G1-96-2 MARINE CORPS TM 2815-24/5 e. Inspect other components for damage such as broken terminals or insulation, discoloration, stripped threads, and other obvious damage. f. Replace damaged components as necessary. 3-11.5.  Testing. a. Set multimeter for ohms and check brush assembly (refer to FIGURE 3-8) for continuity between mount A and brush B, and mount C and brush D.  Check for open circuits between mount A and mount C, mount A and brush D, mount C and brush B, and brush B and brush D.  Replace brush assembly if indications are other than stated. FIGURE 3-8.  Testing Brush Assembly b. Set multimeter for ohms and check diode-trio assembly (refer to FIGURE 3-9) by noting multimeter indications between D+ stud and each of stator terminals.  Reverse multimeter leads, repeat checks and note indications. If readings are the same in both directions for any diode, replace entire diode-trio assembly.  A good diode will show a high indication in one direction and a low indication in the other. FIGURE 3-9.  Testing Diode-Trio 3-31


 