c.
Set multimeter for ohms and check rectifier bridge assembly (refer to FIGURE 3-10) by noting multimeter
indications between point A and each point C, and between point B and each point C. Reverse leads, repeat
checks, and note indications. If readings are the same in both directions for any diode, replace entire rectifier
bridge assembly. A good diode will have a high indication in one direction and a low indication in the other.
FIGURE 3-10. Testing Rectifier Bridge
d.
Set multimeter for ohms and check stator (refer to FIGURE 3-11) for open circuits between point D (lamination)
and each terminal A, B, and C. If continuity is noted between lamination and any terminal, stator is defective and
must be replaced.
e.
Set multimeter for ohms and check stator windings (refer to FIGURE 3-11) for continuity between terminals A-B,
A-C, and B-C. If open, replace stator.
f.
Set multimeter for ohms and check rotor assembly (refer to FIGURE 3-12) for 12.0 to 13.0 ohms indication
between slip rings. Also check that open circuits are indicated between pole fingers and each slip ring. Replace
entire rotor assembly if indications are other than stated.
3-11.6. Assembly.
a.
Using press, install front bearing (32, FIGURE 3-6) in front housing (30).
3-32
|
|