TM 9-2920-243-34 (4) Inspect armature shaft alinement and commutator for eccentricity to shaft with a lathe or V-blocks and a dial indicator (fig. 3-28). Check armature shaft for true alinement. If shaft runout exceeds  0.005-inch,  commutator  of  armature shaft  must  be  resurfaced  provided  it  will  not  be cut below limits specified in repair and rebuild standards  (para  3-31  a). If  commutator  requires cutting  below  limits  specified,  replace  starter. Figure 3-27. Testing armature for short circuits. Figure 3-26. Testing armature for grounds. 3-11


 