AIR FORCE TO 35C2-3-505-1
Table 2-2. Operator Preventive Maintenance Checks and Services
for AN/MJQ-1612 andAN/MJQ-1632 (Continued)
Item
Interval
Location
Procedure
Not Fully Mission Capable if:
No.
Item to Check/Service
TRAILER continued
13
Before
ACCESSORIES
Check that the following
Fire extinguishers missing or
accessories are not missing or
seal open.
damaged:
Auxiliary fuel hose
Fire extinguishers, check
seal.
NOTE
Remaining accessories are
Ground rod and/or ground
stored in accessory box.
cable missing.
Fuel container adapter
Ground rod
Hammer, 8 lb.
Slide hammer
Ground cable
Oil drain hose
GENERATOR SET
Cannot secure doors.
14
Before
HOUSING
Check doors, panels, hinges,
and latches for damaged,
loose or corroded items.
Inspect air intake and exhaust
grills for debris.
15
Before
ACOUSTICAL
Ensure that acoustical
MATERIALS
materials are free of damage
or not missing.
WARNING
With any access door open, the noise level of this generator set could cause
hearing damage. Hearing protection must be worn when working near the
generator set while running.
WARNING
The fuels used in this generator set are highly explosive. DO NOT smoke or use
open flame when performing maintenance. Flames and explosion can occur
resulting in severe personal injury or death.
16
Before
ENGINE ASSEMBLY
Check for loose, damaged, or
missing hardware.
2-18
|
||