|  ARMY TM 9-6115-666-13&P AIR FORCE TO 35C2-3-505-1 Table 2-2. Operator Preventive Maintenance Checks and Services for AN/MJQ-1612 and AN/MJQ-1632 Item Interval Location Procedure Not Fully Mission Capable if: No. Item to Check/Service GENERATOR SET - continued 17 Before FUEL SYSTEM Inspect fuel system for leaks, Any fuel leaks, damaged, loose damaged, loose or missing or missing parts. parts Any fuel leaks. 18 Before FUEL a. Inspect fuel filter/water FILTER/WATER separator (11) for leaks, SEPARATOR proper mounting, cracks, damage, or missing parts Fuel filter/water separator not b. Drain water from fuel drained. filter/water separator into appropriate container. Drain hose is located in battery box 19 Before ETHER START a. Check for deteriorated, SYSTEM loose or missing parts. Class III leaks. Damaged, loose 20 Before LUBRICATION a. Inspect for leaks, or missing parts. SYSTEM damaged, loose or missing parts. Oil level is below ADD level b. Check engine oil level (12). Add as necessary c. Check engine oil for Engine oil shows signs of WARNING Cooling system operates at high temperatures. Personal injury or death from burns or scalding can result from contact with high pressure steam and/or liquid. COOLING SYSTEM 21 Before RADIATOR Check radiator (13) for leaks, Class III leaks. Radiator cap damage or missing parts. missing. 2-19 | ||
|  | ||