Custom Search
 
  
 
ARMY TM 9-6115-666-13&P
AIR FORCE TO 35C2-3-505-1
Table 2-2. Operator Preventive Maintenance Checks and Services
for AN/MJQ-1612 and AN/MJQ-1632
Item
Interval
Location
Procedure
Not Fully Mission Capable if:
No.
Item to Check/Service
GENERATOR SET -
continued
17
Before
FUEL SYSTEM
Inspect fuel system for leaks,
Any fuel leaks, damaged, loose
damaged, loose or missing
or missing parts.
parts
Any fuel leaks.
18
Before
FUEL
a. Inspect fuel filter/water
FILTER/WATER
separator (11) for leaks,
SEPARATOR
proper mounting, cracks,
damage, or missing parts
Fuel filter/water separator not
b. Drain water from fuel
drained.
filter/water separator into
appropriate container.
Drain hose is located in
battery box
19
Before
ETHER START
a. Check for deteriorated,
SYSTEM
loose or missing parts.
Class III leaks. Damaged, loose
20
Before
LUBRICATION
a. Inspect for leaks,
or missing parts.
SYSTEM
damaged, loose or
missing parts.
Oil level is below ADD level
b. Check engine oil level (12).
Add as necessary
c. Check engine oil for
Engine oil shows signs of
WARNING
Cooling system operates at high temperatures. Personal injury or death from
burns or scalding can result from contact with high pressure steam and/or liquid.
COOLING SYSTEM
21
Before
RADIATOR
Check radiator (13) for leaks,
Class III leaks. Radiator cap
damage or missing parts.
missing.
2-19


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business