Item
Interval
Location
Procedure
Not Fully Mission Capable if:
No.
Item to Check/Service
WARNING
The fuels used in this generator set are highly explosive. DO NOT smoke
or use open flame when performing maintenance. Flames and explosion
can occur, resulting in severe personal injury or death.
WARNING
Exercise extreme caution when performing "DURING" checks inside
engine compartment. Avoid contact with moving or hot engine parts.
Failure to observe this warning can result in severe personal injury or
death.
GENERATOR SET -
continued
40
During
ENGINE ASSEMBLY
Check for loose, damaged or
missing parts.
41
During
FUEL SYSTEM
Inspect for leaks.
Any fuel leaks.
Class III leaks.
42
During
LUBRICATION
a. Inspect for leaks
Oil level below ADD level.
SYSTEM
b. Check oil level on dipstick,
both sides.
43
During
COOLING FAN
Listen for unusual noise in fan
area.
Cable is missing or damaged.
Inspect ground rod and cable
44
During
GROUND ROD
for loose connections, breaks,
CABLE AND
damage, and corrosion.
CONNECTIONS