Custom Search
 
  
 
ARMY TM 9-6115-666-13&P
AIR FORCE TO 35C2-3-505-1
Table 2-2. Operator Preventive Maintenance Checks and Services
for AN/MJQ-1612 and AN/MJQ-1632
Item
Interval
Location
Procedure
Not Fully Mission Capable if:
No.
Item to Check/Service
GENERATOR SET -
continued
45
During
CONTROLS AND
Observe the following
INDICATORS
indicators and ensure they are
functioning
 Coolant temp, 170-200
F
(77- 93 )
C
 Oil pressure, 25-60 psi
(172- 414 kPA)
46
During
AUXILIARY FUEL
Inspect for leaks.
Any fuel leaks.
SYSTEM
Cannot secure doors.
47
After
HOUSING
a. Check doors, panels,
hinges, and latches for
drainage, loose, or
corroded items.
b. Inspect air intake and
Intake and exhaust grills
exhaust grills for debris.
plugged
48
After
IDENTIFICATION
Check to be sure identification
PLATES
plates are secure.
49
After
SKID BASE
Inspect skid base for cracks
Skid base cracked or. shows
and corrosion
signs of structural damage.
WARNING
DO NOT smoke or use flame near this generator set. The fuels used in it
are highly explosive. Flames and explosion can occur, resulting in severe
personal injury or death.
50
After
ENGINE ASSEMBLY
Check for loose, damaged, or
missing hardware.
51
After
FUEL SYSTEM
Inspect fuel system for leaks,
Any fuel leaks, damaged,
damaged, loose, or missing
loose, or missing parts.
hardware.
2-25


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business