5.10. CABLE ASSEMBLY MAINTENANCE (Continued).
Table 5-6. Cable Assembly W1
Wire Color
From
To
BLUE
A1S1-LN6
L3
RED
A1S1-LN4
L2
BLACK
A1S1-LN2
L1
WHITE
A1W4-7(N)
N
GREEN
A1W5-11(GND)
GND
Table 5-7. Cable Assembly W2.
Wire Color
From
To
BLUE
A1S2-LN6
L3
RED
A1S2-LN4
L2
BLACK
A1S2-LN2
L1
WHITE
A1W4-7(N)
N
GREEN
A1W5-12(GND)
GND
REPAIR
Refer to appendix H and repair or manufacture cable assembly.
INSTALLATION
1. Route cable assembly through power cable sock (1 4) on generator set (1 5).
2. Route cable assembly through stuffing tube (3) on switch box assembly.
3. Connect cable (1) as shown in table 5-6 or table 5-7 and FO-1, wiring diagram.
4. Connect cable terminal ends (7) to input switch (8) using flat washers (6), lock washers (5), and new
lock nuts (4)
5. Connect cable terminal ends (12) to bus bar (13) using screws (1 1), flat washers (10) and new lock
nuts (9).
6. Install two clear plastic panel covers and switch box cover.