Quantcast Installation - TM-9-2815-202-34_549

Custom Search
 
  
 
TM9-2815-202-34 d. Assembly (1) Install gasket (16) and breather pipe (15) onto adaptor (12). Secure with two Iockwashers (14) and two bolts (13). Torque bolts to 30-35 Ib-ft (41 -47 N-m). (2) Install filter element (10) and shell (11) onto adaptor (12) and secure with spacer (9), flat washer (8), and bolt (7). Torque bolt to 30-35 Ib-ft (41-47 N-m). e.  Installation (1) Install gasket (6) onto breather assembly (5). (2) Position breather assembly (5) onto flywheel housing and secure with two bolts (1), bolt (2), three bolts (3), and six Iockwashers (4). Torque bolts to 30-35 Ib-ft (41-47 N-m). 7-13


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc.
6230 Stone Rd, Unit Q Port Richey, FL 34668

Phone For Parts Inquiries: (727) 493-0744