TM   5-2815-241-34&P LUBRICATING  OIL  PUMP  INSTALLATION  -  CONTINUED ACTION LOCATION ITEM REMARKS 5. Cylinder block (3) Oil  pump  gear  (6) a. Rotate gear in one direction as far as it will   move. b. Set dial indicator to zero. c. Rotate  gear  in  opposite  direction  and check  dial  indicator  reading  for  backlash of 0.002 to 0.016 inch (0.051 to 0.40  mm). TASK  ENDS  HERE T A    2 4 2 3 9 1 2-89


 