TM 5-2815-241-34&P
CAM FOLLOWER ASSEMBLY - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
DISASSEMBLY - CONTINUED
5. Cam follower
lever (1)
Roll pin (2)
Using 16-ounce ball-peen hammer and
3/32-inch drive-pin punch, drive out.
Discard roll pin.
6.
Cam follower roller
pin (3)
a.
Using arbor press and ST-970 plug driv-
ing mandrel, press out of cam follower
lever (1).
b.
Remove cam follower roller (4).
CLEANING
NOTE
For general cleaning procedures, see General Maintenance Instructions, page 2-3.
INSPECTION
WARNING
Drycleaning solvent P-D-680 is toxic and flammable. Wear safety goggles and gloves
and use only in a well-ventilated area. Avoid contact with skin, eyes, and clothes and do
not breathe vapors. Do not use near open flame or excessive heat. Flashpoint for type
#1 drycleaning solvent is 100°F (38°C) and for type #2 is 138°F (59°C). If you become
dizzy while using solvent, get fresh air immediately, and get medical aid. If contact with
eyes is made, wash your eyes with water, and get medical aid immediately. Failure to
observe these precautions could cause serious injury or death to personnel.
Particles blown by compressed air are hazardous. Make certain the air stream is
directed away from user and other personnel in the area. Compressed air used for
cleaning purposes shall not exceed 30 psi (207 kPa). User must wear safety goggles or
face shield to prevent injury.
7.
Cam follower
lever (1)
Wipe clean with rag and inspect for breaks or
clogged oil passages. Check for cracks and
imperfections by visual and magnetic
inspection.
If broken or cracked, replace. If
oil passages are clogged, clean with
drycleaning solvent and use com-
pressed air to thoroughly clean oil
passages.
2-256
|
|