TM 5-3895-360-13
7-3. AIR CLEANER MAINTENANCE (VR11C) (Cont).
b,
c.
WARNING
Dry cleaning solvent, P-D-680, is toxic and
flammable. Always wear protective goggles
and gloves, and use only in a well-ventilated
area. Avoid contact with skin, eyes, and
clothes, and DO NOT breathe vapors. DO NOT
use near open flame or excessive heat. The
solvents flash point is 100°F-138°F
(38 °C-590C). If you become dizzy while using
cleaning solvent, immediately get fresh air and
medical help. If solvent contacts eyes, immedi-
ately wash your eyes and get medical aid.
Clean access cover (2) with dry cleaning solvent
(Item 16, Appendix E) and allow to dry.
Install new filter (3) and access cover (2) on handle
(4) with wingnut (1).
Figure 7-3. Air Cleaner Air Fitter
Replacement (VR11C).
AIR CLEANER REMOVAL
NOTE
Refer to Figure 7-4, Air Cleaner Replacement
(VR11C), for steps a through c.
a. Loosen two clamps (11). Remove hose (12) and
clamps from handle (4) and elbow (8).
b. Remove two screws (10), Iockwashers (9), elbow
(8), and gasket (7) from carburetor (6). Discard lock-
washers and gasket.
c. Remove air cleaner filter (5).
AIR CLEANER INSTALLATION
a.
b.
c.
NOTE
Refer to Figure 7-4, Air Cleaner Replacement
(VR11C), for steps a through c.
Install air cleaner filter (5).
Install new gasket (7) and elbow (8) on carburetor(6)
with two new Iockwashers (9) and screws (10).
Position hose (12) and two clamps (11) on handle (4)
and elbow (8). Tighten two clamps.
7-4
.
.
.
|
|