TM 9-2520-272-34&P
4-18.
INSTALL TRANSMISSION TOP COMPONENTS
(SHEET 13 OF 16)
Look for letters A, B, C, D, E, F and G stamped on
wiring harness connectors (1).
Locate solenoids A, B, E, F and G on main control
valve assembly (2) and locate solenoids C and D on
lockup control valve assembly (3).
Match wiring harness connectors (1) with solenoid
connectors (4).
Hold harness connector (1) and solenoid connector (4)
with ends of connectors facing each other.
Rotate connectors (1, 4) so that connector loops (s)
will fit over bayonets (6).
push connectors (1,4) together until ends of connector
loops (5) are down behind ends of bayonets (6)
1
2
3
4
5
6
7 Install 5/16-18 x 2-3/4 inch bolt (7) through washer (8) and through eye of harness ground
connector (9).
8 using socket, install bolt (7) through main control valve assembly (2).
9 Using torque wrench, tighten bolt (7) to 17-20 lb-ft (23-27 Nn).
Go to Sheet 14
Para. 4-18, Task 7
4-92
|
|