TM    9-2815-202-34 c.   Cleanlng/inspection WARNING Compressed  air  used  for  cleaning  purposes  will  not  exceed  30  psi.  Use only  with  effective  chip  guarding  and  personal  protective  equipment (goggles/  shield,  gloves,  etc). (1) Wash components with fuel oil and dry with compressed air. (2)  Inspect  components  for  excessive  wear,  cracks,  or  damage  and  replace  if  necessary. d.  Assembly (1) Left bank injector control tube (a) (b) (c) (d) (e) (f) Install return spring (17) on control tube (16) and against front bracket (8). Install control lever (9) and left hand helix yield spring (15) on control tube (16). Control lever must face rear of control tube. Install three right hand helix yield springs (14) and three control levers (9) on control tube (16). Control levers must face rear of control tube. Attach curled end of four yield springs (14 and 15) to four control levers (9) and roll yield springs into notch or slots in control tube (16). Turn four adjusting screws (13) with four nuts (12) into slots far enough to position levers on control tube. Attach curled end of control tube return spring (17) to control lever (9) and extended end of spring behind front bracket (8). Install bracket (8) to rear of control tube (16). 4-95


 