TM 9-2815-202-34
c. Cleanlng/inspection
WARNING
Compressed air used for cleaning purposes will not exceed 30 psi. Use
only with effective chip guarding and personal protective equipment
(goggles/ shield, gloves, etc).
(1) Wash components with fuel oil and dry with compressed air.
(2) Inspect components for excessive wear, cracks, or damage and replace if necessary.
d. Assembly
(1) Left bank injector control tube
(a)
(b)
(c)
(d)
(e)
(f)
Install return spring (17) on control tube (16) and against front bracket (8).
Install control lever (9) and left hand helix yield spring (15) on control tube (16). Control
lever must face rear of control tube.
Install three right hand helix yield springs (14) and three control levers (9) on control
tube (16). Control levers must face rear of control tube.
Attach curled end of four yield springs (14 and 15) to four control levers (9) and roll yield
springs into notch or slots in control tube (16). Turn four adjusting screws (13) with four
nuts (12) into slots far enough to position levers on control tube.
Attach curled end of control tube return spring (17) to control lever (9) and extended end
of spring behind front bracket (8).
Install bracket (8) to rear of control tube (16).
4-95
|
|