TM 9-2815-202-34 b.  Cleaning l l Compressed air used for cleaning purposes will not exceed 30 PSI. Use only with effective chip guarding and personal protective equipment (goggles/shield, gloves, etc.) Dry cleaning solvent P-D-680 is toxic and flammable. Wear protective goggles and gloves and use in a well-ventilated area. Avoid contact with skin, eyes, and clothes. Do not breathe vapors. Do not use near  open flame or excessive heat. The flash point is 100-138°F (38-50°C). If you become dizzy while using cleaning solvent, get fresh air immediately and seek medical aid. If contact with eyes is made, wash with water and get medical aid immediately. Never  use  caustic  cleaning  solution  for  cleaning.  Do  not  use  wire  brush  or  steel  blade scraper to clean parts. Such cleaning will damage finished surfaces of turbocharger. NOTE Before cleaning, inspect parts for signs of burning, rubbing, or other damage which might not be evident after cleaning. Insure compressor and turbine wheel blades are thoroughly clean. Deposits left on blades will affect balance of rotating assembly. (1) Soak all parts in cleaning solvent for 25 minutes. After soaking, use a stiff bristle brush to remove all dirt particles. Using compressed air, dry all parts thoroughly. (2) Clean all internal cavities and oil passages in center housing thoroughly with compressed air. (3) Clean oil passage in center housing thrust plate with compressed air. C h a n g e    1 5-97


 