TM9-2815-202-34
e. Test/Adjustment
(1)
(2)
(3)
(4)
(5)
(6)
Connect end of hose (8) to inlet port and hose (6) to outlet port of pump.
Attach a 24 V dc power source to pump and motor assembly (2). After pump is primed and
fuel flow established, flow with no restrictions is 0.2 GPM.
Connect a pressure gage and cutoff valve to hose (6) and power up pump. Pressure with
outlet shut off must be 40 PSI minimum.
Connect a vacuum gage and cutoff valve to hose (8) and power up pump. Suction with inlet
shut off must be 18 inches of mercury minimum.
Disconnect 24 V dc power source.
Remove gages, valves, and hoses (6 and 8) from pump and motor assembly (2).
6-17
|
|