TM 9-2815-202-34
4-42. GOVERNOR REPAIR (Cont)
(45) Remove spacer (89), operating shaft
(85), upper operating lever bearing
(90), and operating lever (68) from
governor housing (3). Slide spacer
(89) from shaft (85).
CAUTION
When pressing operating shaft from
operating lever and bearing, catch
shaft by hand to prevent it from
falling and being damaged.
(46)
(47)
(48)
(49)
(50)
Press operating shaft (85) from upper
bearing (90) and operating lever (68).
Loosen locknut (91 ) and remove
adjusting screw (92).
If damaged, remove pin (66) from
operating lever (68).
Press lower bearing (86) from
governor housing (3).
For model 7083-7395 only, hold
starting aid screw (93) and remove
nut (94) from governor housing (3).
CAUTION
External starting aid screw can only be removed by screwing inward through governor
housing. Removing the screw outward through the governor housing will damage the
threads in the housing due to oversize button on end.
(51 ) Remove external starting aid screw (93) through governor housing (3) by turning screw
clockwise.
b. Cleaning/Inspection
l
l
4-254
WARNING
Dry cleaning solvent P-D-680 is toxic and flammable. Wear protective
goggles and gloves and use only in a well-ventilated area. Avoid
contact with skin, eyes, and clothes and dont breathe vapors. Do not
use near open flame or excessive heat. The flash point is 100oF-138°F
(38°C-50oC). If you become dizzy while using cleaning solvent, get
fresh air immediately and get medical aid. If contact with eyes is made,
wash your eyes with water and get medical aid immediately.
Compressed air used for cleaning purposes will not exceed 30 PSI.
Use only with effective chip guarding and personal protective
equipment (goggles/shield, gloves, etc.).
|
|