Tweet |
Custom Search
|
|
|
||
TM 9-2815-220-24
WIRING HARNESS AND CABLE REPAIR
0056 00
REPLACEMENT OF CONNECTORS (Continued)
Disassembly of Typical Male-Type Plug with Ridged Locking Nut
1. Heat boot (A) on shell assembly (B) and roll back on cable (C).
2. Unscrew nut (D) from shell assembly (B) and slide back on cable (C).
3. Drive pin contacts (E) out through rear of shell (F) with pin extractors.
4. Using soldering gun (item 108, WP 0176), unsolder or cut cable (C) leads from pin
contacts (E).
Assembly of Typical Male-Type Plug with Ridged Locking Nut
1. Strip cable (C) insulation equal to depth of wells in pin contacts (E).
2. Insert cable (C) leads into wells of pin contacts (E) and solder (using item 38, WP 0173) or
crimp.
3. Push pin contacts (E) into shell (F) from rear until seated.
4. Screw nut (D) onto shell assembly (B).
5. Apply a thin even layer of adhesive (item 1, WP 0173) to shell assembly (B) and roll boot (A)
onto shell assembly (B).
B
A
C
E
E
D
F
WP 0056 00-19
|
||